sst RVS Manifolds

Increasingly, projects—both residential and commercial—are being carried out with both heating and cooling capabilities.

sst stalen verdelers

An air-to-water heat pump system is suitable for heating, cooling, and domestic hot water production. The stainless steel manifold is ideal for low-temperature systems supplied without mixing. The stainless steel manifold is corrosion-free, and each circuit is equipped with its own flow regulator. This pump-free manifold is suitable for both heating and cooling.

3/4'' EuroConus

3/4'' EuroConus

Flow meter, adjustable
0 to 2.5 liters per minute

Supply connection 1”

Return connection 1”

When using control,
combine with adapter VA 80

Group shut-off valve
thermostatically prepared
(M30 x 1.5)

Filling and drain valve

Filling and drain valve

SST RVS Smart

This pump-free stainless steel manifold is standard equipped with the capability for both heating and cooling.

Specifications

Heating

Cooling

Mixing control with pump

Low temperature

District heating up to 10 bar

Separate circuit

Automatic flow rate

Material: stainless steel (Inox)
Maximum operating pressure: 10 bar
Supply/return connection: ¾”
Number of groups: 2 to 18

SST RVS MANIFOLDS

Low temperature

The manifold is the beating heart of a water-based underfloor heating system. The starting point is that the water supply is heated by a primary heat source. The supply temperature of the heat source determines which type of manifold needs to be installed.

What is low temperature?

We refer to low-temperature (LT) systems when the supply temperature from the primary heat source ranges between 30 °C and 65 °C. Within this range, a distinction is made between open LT systems (up to a maximum supply temperature of 45 °C) and LTV systems (up to a maximum supply temperature of 65 °C). In most cases, heating is provided by a (hybrid) heat pump or a boiler with a supply temperature of up to 65 °C.

When underfloor heating is connected to a central heating system with a supply temperature of up to 45 °C, open manifolds (without pumps) are usually used. In these systems, the pump from the primary heat source circulates the supply water through both the central heating system and the floor.

For sustainability reasons, homes are increasingly being equipped with low-temperature systems. All steel manifolds from SST are designed for low-temperature systems. This is both in response to market demand and because we want to contribute to a livable future for generations to come.

Want to read more about our products?

Then browse through our product catalog.

Follow us on social media

Tacker plate production

Take a look at our newest production facility

View the full product range?

Download the catalog!

Direct to FHICS?

The software for underfloor heating

Coming soon..