- Voor een simpele en snelle montage
- Overlappend verleggen.
- Uitstekend akoestisch dempend
sst Composite manifolds
Composite underfloor heating manifolds are suitable for both heating and cooling. No condensation forms on the manifolds during cooling, and the material exhibits minimal shrinkage at low temperatures. This prevents leaks at the connections.
Our Premium composite manifolds are suitable for low-temperature underfloor heating installations and are used as primary or secondary heating. In low-temperature systems, the supplied water already has the correct temperature, allowing it to be sent directly into the floor almost immediately. The water is circulated by, for example, a heat pump, and the manifold ensures proper distribution over the heating pipes. These manifolds are increasingly used with heat pumps, enabling heating in winter and cooling in summer.
For control, combine with adapter VA 10
3/4'' EuroConus
3/4'' EuroConus
Group valve
thermostatically prepared
(M30x1.5)
Air vent valve
Air vent valve
Flow meter, adjustable
0 to 2.5 liters per minute
Connection
supply 1''
Valve equipped with
thermometer & fill/drain valve
Valve equipped with
thermometer & fill/drain valve
Connection
return 1''
Basic manifold 1''
Manufactured from high-quality composite (polyamide housing reinforced with 50% glass fiber). Pumpless.
Specifications
Heating
Cooling
Mixing control with pump
Low temperature
District heating up to 10 bar
Separate circuit
Automatic flow rate
Material: Composite
Maximum operating pressure: 4 bar
Connection supply / return: 1”
Number of groups: 2 to 12
Connection
return (5/4'')
Connection
return (5/4'')
Air vent valve
Air vent valve
Thermometer
Thermometer
Filling and draining valve
Filling and draining valve
Group valve thermostatically prepared (M30x1.5)
Flow meter, adjustable
0 to 5 liters per minute
3/4'' EuroConus
3/4'' EuroConus
For control, combine
with adapter VA 10
5/4'' manifold
This manifold consists of separate blocks, is fully assembled, and is suitable for primary and secondary heating as well as cooling.
Specifications:
Heating
Cooling
Mixing control with pump
Low temperature
District heating up to 10 bar
Separate circuit
Automatic flow rate
Material: Composite
Maximum operating pressure: 4 bar
Connection supply/return: 1¼” (5/4”)
Number of groups: 2 to 20
Circulation pump
Air vent valve
Air vent valve
Fill and drain valve
Fill and drain valve
Thermometer
Thermometer
Flow meter, adjustable
0 to 5 liters per minute
Group valve
thermostatically prepared
(M30x1.5)
For control, combine with adapter VA 10
3/4'' EuroConus
3/4'' EuroConus
3/4'' manifold with pump
An even distribution of heating and/or cooling water in the floor ensures optimal comfort.
Specifications:
Heating
Cooling
Mixing control with pump
Low temperature
District heating up to 10 bar
Separate circuit
Automatic flow rate
Material: Composite
Maximum operating pressure: 4 bar
Connection supply/return: ¾”
Number of groups: 2 to 16
3/4'' EuroConus
3/4'' EuroConus
Fill and drain valve
Fill and drain valve
Thermometer
Thermometer
Connection 1'' return
Connection 1'' supply
Connection 1'' supply
Flow meter, adjustable
0 to 2.5 liters per minute
Group valve
thermostatically prepared
(M30x1.5)
For control, combine with adapter VA 10
CONNECTION OPTIONS
The SST composite compact manifold can be supplied with 3 different pump modules, which include features such as a circulation pump, heat exchanger, and an expansion vessel.
SST composite compact +
With optional pump mixing module
Specifications
Heating
Cooling
Low temperature
District heating up to 10 bar
Automatic flow rate
Mixing control with pump
In combination with the modules below
Separate circuit
In combination with the modules below
Material: Composite
Maximum operating pressure: 2 bar (due to safety)
Supply/return connection: 3/4”
Number of groups: 2 to 12
ChatGPT zei:
The heart of the underfloor heating system is the manifold. The manifold module receives heated or cooled water and distributes it through the pipes in the floor. These pipes then warm (or cool) the room. Depending on the situation, user preferences, and the chosen system, more or fewer components may be required.
2-pipe pump module
With expansion vessel (without DHW)
For heating purposes
2-pipe pump module
With expansion vessel and heat exchanger District heating
For heating purposes
4-pipe pump module
With expansion vessel and heat exchanger
For heating & cooling
Circulation pump
Expansion vessel
Overflow valve
Heat exchanger
Circulation pump
Immersion tube + sensor
Overflow valve
Thermostat
Valve
RTL valve
Expansion vessel
Circulation pump
Overflow valve
Overflow valve
RTL-Valve
Thermostatic valve
double adjustable with
control element 20-50 °C
Heat exchanger
Suitable for situations where the primary and secondary circuits need to be hydraulically separated. For example: high pressure/temperature (district) heating, different transport media in the primary circuit, or renovation where no oxygen-tight pipe is used in the secondary circuit.
More info? View our catalog:
SST Composite manifolds
Quality manifolds
Our composite manifolds are modularly constructed and equipped with thermo/manometers, adjustable flow meters, and integrated valves (onto which thermostatic actuators can be mounted).