sst Composite manifolds

Composite underfloor heating manifolds are suitable for both heating and cooling. No condensation forms on the manifolds during cooling, and the material exhibits minimal shrinkage at low temperatures. This prevents leaks at the connections.

Our Premium composite manifolds are suitable for low-temperature underfloor heating installations and are used as primary or secondary heating. In low-temperature systems, the supplied water already has the correct temperature, allowing it to be sent directly into the floor almost immediately. The water is circulated by, for example, a heat pump, and the manifold ensures proper distribution over the heating pipes. These manifolds are increasingly used with heat pumps, enabling heating in winter and cooling in summer.

For control, combine with adapter VA 10

3/4'' EuroConus

3/4'' EuroConus

Group valve
thermostatically prepared
(M30x1.5)

Air vent valve

Air vent valve

Flow meter, adjustable
0 to 2.5 liters per minute

Connection
supply 1''

Valve equipped with
thermometer & fill/drain valve

Valve equipped with
thermometer & fill/drain valve

Connection
return 1''

Basic manifold 1''

Manufactured from high-quality composite (polyamide housing reinforced with 50% glass fiber). Pumpless.

Specifications

Heating

Cooling

Mixing control with pump

Low temperature

District heating up to 10 bar

Separate circuit

Automatic flow rate

Material: Composite
Maximum operating pressure: 4 bar
Connection supply / return: 1”
Number of groups: 2 to 12

Connection
return (5/4'')

Connection
return (5/4'')

Air vent valve

Air vent valve

Thermometer

Thermometer

Filling and draining valve

Filling and draining valve

Group valve thermostatically prepared (M30x1.5)

Flow meter, adjustable
0 to 5 liters per minute

3/4'' EuroConus

3/4'' EuroConus

For control, combine
with adapter VA 10

5/4'' manifold

This manifold consists of separate blocks, is fully assembled, and is suitable for primary and secondary heating as well as cooling.

Specifications:

Heating

Cooling

Mixing control with pump

Low temperature

District heating up to 10 bar

Separate circuit

Automatic flow rate

Material: Composite
Maximum operating pressure: 4 bar
Connection supply/return: 1¼” (5/4”)
Number of groups: 2 to 20

Circulation pump

Air vent valve

Air vent valve

Fill and drain valve

Fill and drain valve

Thermometer

Thermometer

Flow meter, adjustable
0 to 5 liters per minute

Group valve
thermostatically prepared
(M30x1.5)

For control, combine with adapter VA 10

3/4'' EuroConus

3/4'' EuroConus

3/4'' manifold with pump

An even distribution of heating and/or cooling water in the floor ensures optimal comfort.

Specifications:

Heating

Cooling

Mixing control with pump

Low temperature

District heating up to 10 bar

Separate circuit

Automatic flow rate

Material: Composite
Maximum operating pressure: 4 bar
Connection supply/return: ¾”
Number of groups: 2 to 16

3/4'' EuroConus

3/4'' EuroConus

Fill and drain valve

Fill and drain valve

Thermometer

Thermometer

Connection 1'' return

Connection 1'' supply

Connection 1'' supply

Flow meter, adjustable
0 to 2.5 liters per minute

Group valve
thermostatically prepared
(M30x1.5)

For control, combine with adapter VA 10

CONNECTION OPTIONS

The SST composite compact manifold can be supplied with 3 different pump modules, which include features such as a circulation pump, heat exchanger, and an expansion vessel.

SST composite compact +

With optional pump mixing module

Specifications

Heating

Cooling

Low temperature

District heating up to 10 bar

Automatic flow rate

Mixing control with pump

In combination with the modules below

Separate circuit

In combination with the modules below

Material: Composite
Maximum operating pressure: 2 bar (due to safety)
Supply/return connection: 3/4”
Number of groups: 2 to 12

ChatGPT zei:

The heart of the underfloor heating system is the manifold. The manifold module receives heated or cooled water and distributes it through the pipes in the floor. These pipes then warm (or cool) the room. Depending on the situation, user preferences, and the chosen system, more or fewer components may be required.

2-pipe pump module

With expansion vessel (without DHW)
For heating purposes

2-pipe pump module

With expansion vessel and heat exchanger District heating
For heating purposes

4-pipe pump module

With expansion vessel and heat exchanger
For heating & cooling

Circulation pump

Expansion vessel

Overflow valve

Heat exchanger

Circulation pump

Immersion tube + sensor

Overflow valve

Thermostat
Valve

RTL valve

Expansion vessel

Circulation pump

Overflow valve

Overflow valve

RTL-Valve

Thermostatic valve
double adjustable with
control element 20-50 °C

Heat exchanger

Suitable for situations where the primary and secondary circuits need to be hydraulically separated. For example: high pressure/temperature (district) heating, different transport media in the primary circuit, or renovation where no oxygen-tight pipe is used in the secondary circuit.

More info? View our catalog:

SST Composite manifolds

Quality manifolds

Our composite manifolds are modularly constructed and equipped with thermo/manometers, adjustable flow meters, and integrated valves (onto which thermostatic actuators can be mounted).

Follow us on social media

Tacker plate production

Take a look at our newest production facility

View the full product range?

Download the catalog!

Direct to FHICS?

The software for underfloor heating

Coming soon..